EGT
This sensor gives a too weak signal and at the
moment we have an error of 100 degrees!
For everything to work well still need a signal amplifier.
AD8495
https://www.aliexpress.com/w/wholesale-AD8495.html?spm=a2g0o.productlist.search.0To
properly display EGT data on the 3dMFD display, you need a signal
amplifier board.
https://www.aliexpress.com/wholesale?catId=&SearchText=%20AD8495%20ARMZ
This board is needed to increase the signal
amplitude because the signal from the thermocouple is very weak.
https://www.aliexpress.com/item/32679898655.html
EGT - Vcc - 5 volts, GND ground, analog output -
we connect it to the module, IN+ - it connects the thermocouple
there.
the point of this board is to increase the amplitude of the signal,
because the thermocouple has a very weak signal.
EGT - Vcc - 5вольт, GND земля, выход аналоговый его
заводим на модуль, IN+ - туда подключает термопару
Эта плата нужнаа чтобы увеличить амплитуду сигнала потому что с
термопары идет очень слабый сигнал.
Если EGT 817С° max
Нужно заменить резистор подтяжки на GND
на плате 3dMFD с 3кОм на 10кОм
мы просто делим входной сигнал на 2, по этому нам в расчете его надо
умножить на 2, при этом диапазон физического напряжения стал не 3.3
В а, 6.6
Там где 3 стояло ставим 10ком
И в Shel программе, вкладке
User calibrations нужно задать EGT
коэффициент коэффициент коррекции 200/100.
If EGT 817C° max
We need to change the pull-up resistor to GND on the 3dMFD board
from 3kOhm to 10kOhm, we simply divide the input signal by 2, so we
need to multiply it by 2 in the calculation, thus the physical
voltage range became not 3.3V but 6.6V.
Where 3 was 3, we put 10k.
And in Shel program, User calibrations tab we
need to set EGT correction factor 200/100.

|
|